Series OLCT 20 sensors are designed for initial assembly applications, which can be installed in shelters, on skids, for monitoring in very small spaces or for on-board applications.They are mounted via M25 or 3/4" NPT threads or a special accessory to ensure a robust mounting without the need for an additional junction box. The OLCT 20 transmitters provide a 4-20mA output that can be directly connected to PLCs with a maximum current consumption of 100mA at 24VDC.They are certified ATEX explosion-proof by INERIS. The IIC T6, makes them perfectly suited for the detection of hydrogen.
The stainless steel detectors offer protection and resistance to corrosive agents. IP 66 rated, they are resistant to dust and water splashes. The Series OLCT 20's pre-calibrated sensors can be disconnected from the holder by rotation. These 'smart' sensors can be calibrated on a workbench, outside of hazardous areas. Catalytic oxidation sensors for combustible gases are specially treated to resist poisons. They benefit from extremely fast response times and total reliability.
Features
• Stainless steel base